Description
ANTSPACE MD5 Immersion Cooling Mining Container
The ANTSPACE MD5 by BITMAIN is a high-capacity immersion cooling container developed for professional cryptocurrency mining farms. Designed to accommodate up to 160 immersion-cooled ASIC miners, the system provides an operating power capacity of up to 1,000kW and a listed power usage effectiveness rating of 1.06 at 25°C ambient temperature.
Instead of relying on conventional air cooling, the ANTSPACE MD5 places compatible mining servers in dielectric cooling fluid. This approach transfers heat away from critical hardware components, supports stable mining performance and reduces the dependence on high-speed miner fans.
The container is designed for compatible BITMAIN immersion miners, including the ANTMINER S21 Imm. and ANTMINER S21 XP Imm. series. Its modular container format makes the ANTSPACE MD5 suitable for new mining facilities, large-scale expansions and operators upgrading from traditional air-cooled infrastructure.
Explore available equipment in our ASIC miners collection, or browse additional cryptocurrency mining solutions from Hash Titans.
ANTSPACE MD5 Key Features
The ANTSPACE MD5 immersion cooling container combines miner racks, fluid-based heat transfer, power distribution and external heat rejection infrastructure in one large-scale system. This integrated design helps mining operators deploy compatible immersion miners without constructing every cooling component separately.
- Manufacturer: BITMAIN
- Product: ANTSPACE MD5
- Cooling method: Immersion cooling
- Miner capacity: Up to 160 units
- Compatible miners: S21 Imm. and S21 XP Imm.
- Operating power: 1,000kW
- Listed PUE: 1.06 at 25°C ambient temperature
- Input voltage: 400V ±5%
- Frequency: 50/60Hz
- Container format: 40-foot integrated mining solution
- Cooling tower connection: DN65
- Pipe material: 304 stainless steel
ANTSPACE MD5 Technical Specifications
| Manufacturer | BITMAIN |
|---|---|
| Product name | ANTSPACE MD5 |
| Cooling technology | Immersion cooling |
| Container dimensions | 12,192 × 2,438 × 2,896mm |
| Miner capacity | 160 units |
| Compatible miners | ANTMINER S21 Imm. and S21 XP Imm. |
| PUE at 25°C ambient temperature | 1.06 |
| Container certification | China Classification Society Certification |
| Operating power | 1,000kW |
| Input voltage | 400V ±5% |
| Input frequency | 50/60Hz |
| Shipping weight | 12 tonnes |
| Operating weight | 18.5 tonnes |
| Main power-distribution switches | 1,200A × 2 |
| Rated current | Section A: 952A; Section B: 866A |
| Rated current per miner | 20A |
| Cooling tower interface | DN65, ISO 2852 PN16 |
Listed Safety and Equipment Standards
The supplied ANTSPACE MD5 specifications reference several electrical, machinery and industrial safety standards. Final certification requirements may vary according to the installation country, local authority and configuration of the mining facility.
- NFPA 79: 2024
- UL 508A: 2018 R7.22
- CSA C22.2 No. 301:23
- ANSI/ISO 12100: 2012
- EN ISO 12100: 2010
- EN 60204-1: 2018
Mining operators should have the installation reviewed by qualified electrical, mechanical and fire-safety professionals before commissioning the system.
ANTSPACE MD5 Inlet Cable Requirements
The inlet cables used with the ANTSPACE MD5 must withstand voltages above 600V and meet the electrical capacity required by the container. The supplied cable configuration is listed below.
| L1 conductor | Single-core 600kcmil cable, approximately 300mm² × 4 |
|---|---|
| L2 conductor | Single-core 600kcmil cable, approximately 300mm² × 4 |
| L3 conductor | Single-core 600kcmil cable, approximately 300mm² × 4 |
| Neutral conductor | Single-core 600kcmil cable, approximately 300mm² × 4 |
| Protective earth conductor | Single-core 500kcmil cable, approximately 240mm² × 2 |
These connections should only be designed, installed and tested by qualified high-voltage electrical professionals. Cable selection must also comply with local codes, environmental conditions and the actual installation distance.
ANTSPACE MD5 Dry Tower Specifications
The dry tower removes heat transferred from the immersion fluid and helps the ANTSPACE MD5 maintain suitable operating conditions. It is an essential part of the complete cooling system rather than an optional domestic-style ventilation accessory.
| Dry tower dimensions | 12,192 × 2,438 × 2,896mm |
|---|---|
| Outlet temperature at 30°C ambient | 35°C |
| Temperature relationship | Outlet temperature approximately 5°C above ambient |
| Container certification | China Classification Society Certification |
| Operating power | 100kW |
| Motor-rated voltage | 400V ±5% |
| Motor frequency | 50/60Hz |
| Shipping weight | 11.8 tonnes |
| Operating weight | 12.8 tonnes |
| Connection interface | DN65, ISO 2852 PN16 |
| Noise level | 70dB |
| Pipe material | 304 stainless steel |
Advanced ANTSPACE MD5 Immersion Cooling
The ANTSPACE MD5 uses dielectric fluid to absorb heat directly from compatible mining hardware. Because the fluid surrounds heat-producing components, thermal energy can be transferred more evenly than with conventional fan-based air cooling.
This cooling method may reduce temperature fluctuations, limit dust exposure and decrease the mechanical stress associated with high-speed onboard cooling fans. The result is a mining environment designed for stable operation under continuous workloads.
Immersion cooling does not eliminate maintenance. Operators must monitor fluid quality, pumps, seals, pipe connections, heat exchangers, filters and the dry tower. Only fluid approved for the specific equipment and system configuration should be used.
BITMAIN presents the ANTSPACE MD5 as an integrated immersion-cooling platform for large-scale mining deployment. Visit the official BITMAIN ANTSPACE MD5 overview for additional manufacturer information.
Capacity for 160 Immersion-Cooled Miners
The ANTSPACE MD5 supports up to 160 compatible mining servers. This capacity allows operators to consolidate a substantial amount of mining power inside one containerized system.
The listed compatible models include the ANTMINER S21 Imm. and ANTMINER S21 XP Imm. series. Compatibility should always be confirmed before installation because miner dimensions, electrical requirements, firmware and cooling specifications may differ between models or production batches.
The modular internal arrangement also allows sections of the system to be managed independently. This can simplify troubleshooting, planned maintenance and phased deployment when compared with a single undivided cooling circuit.
ANTSPACE MD5 Power Efficiency and PUE
The ANTSPACE MD5 has a listed PUE of 1.06 at an ambient temperature of 25°C. Power usage effectiveness compares the total energy consumed by a facility with the energy delivered directly to its computing equipment.
A PUE close to 1.0 indicates that a relatively small share of total energy is used by supporting infrastructure such as pumps, cooling equipment and power distribution. Actual performance can vary according to climate, miner load, fluid temperature, pump settings, dry tower operation and installation quality.
The mining container has an operating power rating of 1,000kW, while the dry tower has a listed operating power requirement of 100kW. Operators should calculate the complete facility load, including transformers, pumps, lighting, networking and other supporting systems.
ANTSPACE MD5 Deployment Requirements
Deploying the ANTSPACE MD5 requires more than placing the container on an empty site and connecting miners. The project should include civil engineering, high-voltage electrical infrastructure, grounding, fluid management, drainage, networking, fire protection and safe maintenance access.
- Prepare a level foundation capable of supporting the full operating weight.
- Confirm crane, truck and site-access requirements before delivery.
- Install suitable transformers, switchgear and power-distribution equipment.
- Provide a stable 400V ±5%, 50/60Hz electrical supply.
- Install and test all protective-earth and grounding connections.
- Connect the dry tower using the specified DN65 interfaces.
- Fill the cooling circuit with approved dielectric fluid.
- Pressure-test pipes, valves, seals and connections for leaks.
- Connect networking and facility monitoring systems.
- Install compatible miners according to BITMAIN instructions.
- Commission the cooling system before applying full mining load.
- Monitor temperatures, flow rates, electrical load and fluid condition.
Installation and commissioning should be handled by technicians experienced with industrial electrical systems and immersion-cooled mining infrastructure.
Why Choose the ANTSPACE MD5?
The ANTSPACE MD5 is designed for mining companies that need density, scalability and controlled thermal performance. Its primary advantages include support for 160 miners, a 1MW operating capacity, integrated immersion cooling and a containerized design.
The system may also help reduce miner fan noise and airborne dust inside the mining environment. Because compatible miners are cooled through dielectric fluid, operators can build high-density mining facilities without relying exclusively on large volumes of filtered outdoor air.
The ANTSPACE MD5 immersion container is not intended for small residential operations. Its electrical load, physical size, operating weight and infrastructure requirements make it a professional mining-farm solution.
Browse our ASIC mining hardware to compare compatible mining equipment and other large-scale cryptocurrency mining solutions.
ANTSPACE MD5 Frequently Asked Questions
What is the ANTSPACE MD5?
The ANTSPACE MD5 is a containerized immersion cooling system manufactured by BITMAIN for high-density cryptocurrency mining operations.
How many miners can the ANTSPACE MD5 hold?
The system has a listed capacity of up to 160 compatible immersion-cooled mining servers.
Which miners are compatible with the ANTSPACE MD5?
The supplied specifications list the ANTMINER S21 Imm. and S21 XP Imm. series as compatible models.
What is the operating power of the ANTSPACE MD5?
The mining container has a listed operating power capacity of 1,000kW.
What is the PUE of the ANTSPACE MD5?
The listed PUE is 1.06 at an ambient temperature of 25°C. Actual efficiency may vary according to climate, load and system configuration.
What voltage does the container require?
The listed input requirement is 400V ±5% at 50/60Hz.
Does the ANTSPACE MD5 include a dry tower?
The complete solution is designed around an immersion-cooling container and external dry tower used to reject heat from the cooling circuit.
How loud is the dry tower?
The supplied dry tower specification lists a noise level of approximately 70dB.
What is the operating weight?
The mining container has a listed operating weight of 18.5 tonnes. The dry tower has a separate listed operating weight of 12.8 tonnes.
Can the ANTSPACE MD5 be used at home?
No. Its 1MW power capacity, industrial voltage, size and cooling infrastructure make it suitable for professional mining farms rather than residential installations.
Does immersion cooling guarantee mining profitability?
No. Profitability depends on miner efficiency, cryptocurrency prices, network difficulty, electricity costs, facility expenses, uptime and other changing conditions.
Buy ANTSPACE MD5 Mining Infrastructure
The ANTSPACE MD5 provides a scalable immersion-cooling platform for operators deploying up to 160 compatible BITMAIN miners. Its 1,000kW operating capacity, 1.06 listed PUE and integrated dry tower design make it a serious infrastructure option for modern high-density mining farms.
Before ordering, confirm miner compatibility, electrical capacity, site preparation, cooling-fluid requirements, freight costs and local regulatory obligations. Visit Hash Titans to explore the ANTSPACE MD5, compatible ASIC miners and other cryptocurrency mining equipment.





Reviews