Antrack V1 Hydro Cooling Miner Rack
The Antrack V1 is a professional hydro cooling rack developed by BITMAIN for operating multiple compatible ANTMINER hydro miners within one compact system. It supports up to four S19 Hyd. or S21 Hyd. series miners with a combined maximum load of 24kW.
Unlike an individual ASIC mining server, the Antrack V1 provides the supporting infrastructure required to organize power delivery, coolant circulation, networking and heat transfer for several hydro-cooled miners. This makes it suitable for mining farms, hosting providers and professional operators that want to deploy hydro mining without using a full-size container.
The system operates on a three-phase 380–415V electrical supply and requires a coolant flow rate between 32 and 40 litres per minute. With correct installation, the Antrack V1 can help maintain stable operating temperatures while reducing dependence on the high-speed fans used by traditional air-cooled ASIC miners.
Browse compatible equipment in our ASIC miners collection, or explore additional cryptocurrency mining infrastructure available from Hash Titans.
Antrack V1 Key Features
The Antrack V1 hydro cooling rack offers a compact way to deploy several compatible hydro miners within one organized cabinet. It combines server mounting, coolant circulation, industrial power input and Ethernet connectivity in a purpose-built mining solution.
- Manufacturer: BITMAIN
- Model: ANTRACK
- Version: V1
- Infrastructure type: Hydro cooling miner rack
- Miner capacity: Four compatible ANTMINER units
- Supported series: S19 Hyd. and S21 Hyd. series
- Maximum server load: 24kW
- Input voltage: 380–415V
- Input frequency: 50–60Hz
- Input current: 80A
- Coolant flow requirement: 32–40L/min
- Maximum water pressure: 3.5 bar
- Working fluid: 10% antifreeze solution
- Operating temperature: 15–45°C
- Listed warranty: 365 days
Antrack V1 Specifications
| Manufacturer | BITMAIN |
|---|---|
| Model | ANTRACK |
| Version | V1 |
| Infrastructure type | Hydro cooling mining rack |
| Miner capacity | 4 ANTMINER units |
| Compatible miner series | ANTMINER S19 Hyd. and S21 Hyd. series |
| Maximum mining load | 24kW |
| Input voltage | 380–415V |
| Input frequency | 50–60Hz |
| Input current | 80A, three-phase AC |
| Network connection | Ethernet 10/100M |
| Coolant flow rate | 32–40L/min |
| Maximum coolant pressure | 3.5 bar |
| Working fluid | 10% antifreeze solution |
| Required liquid pH | 7.8–8.5 |
| Operating temperature | 15–45°C |
| Storage temperature | -20°C to 70°C |
| Operating humidity | 10–90% RH, non-condensing |
| Listed warranty | 365 days |
Antrack V1 Hardware Configuration
The Antrack V1 is designed as a vertical hydro mining cabinet that houses four compatible ANTMINER servers along with the coolant distribution and control hardware required for operation.
| Dimensions without packaging | 1,000 × 600 × 2,000mm |
|---|---|
| Dimensions with packaging | 2,380 × 1,170 × 805mm |
| Net weight | 205kg |
| Gross weight | 310kg |
| Network mode | Ethernet 10/100M |
The system’s 205kg net weight means that the installation surface must be level, stable and capable of supporting the cabinet, miners, coolant and associated piping.
Delivery planning should account for the packaged dimensions and 310kg gross weight. Suitable lifting equipment may be required to move the Antrack V1 safely into position.
Antrack V1 Miner Compatibility
The Antrack V1 is officially designed for four compatible ANTMINER S19 Hyd. or S21 Hyd. series miners. The combined maximum mining load must not exceed 24kW.
Compatibility should be confirmed using more than the cooling method alone. Before installing a miner, verify:
- The exact ANTMINER model
- The production batch
- The miner’s maximum power consumption
- The physical dimensions
- The coolant inlet and outlet connections
- The required water flow
- The recommended water pressure
- The power connector configuration
- The installed firmware version
Four miners rated at exactly 6kW each would use the full 24kW capacity. Any auxiliary demand and operating tolerance should be considered when planning the final load.
Browse available hydro-cooled ASIC miners to compare potential hardware for an Antrack V1 installation.
Antrack V1 Hydro Cooling Requirements
The Antrack V1 circulates coolant through compatible mining servers to collect heat from internal components. The heated liquid then moves through the external heat-rejection equipment selected for the final installation.
The required flow rate is between 32 and 40 litres per minute, while water pressure must remain at or below 3.5 bar. Insufficient flow can cause miner temperatures to rise rapidly, while excessive pressure can damage hoses, fittings or internal cooling components.
The listed working fluid is a 10% antifreeze solution. This helps provide basic freeze protection and may support corrosion control when the system is prepared according to BITMAIN’s requirements.
The required liquid pH range is 7.8–8.5. Coolant chemistry must be monitored because incorrect pH, excessive conductivity, minerals or contamination can damage the cooling system.
BITMAIN states that the fluid must be replaced when conductivity reaches or exceeds 100μS/cm. The conductivity should be below 20μS/cm when the system is operated for the first time.
For additional manufacturer guidance, review the official BITMAIN Antrack V1 specification and BITMAIN water-quality requirements.
Antrack V1 Electrical Requirements
The Antrack V1 requires a three-phase AC supply between 380V and 415V at 50–60Hz. The listed input-current requirement is 80A.
This is industrial electrical infrastructure and should not be connected to a household outlet or ordinary residential panel. The final system should include:
- Properly sized three-phase conductors
- Protective grounding
- Suitable circuit breakers
- Surge protection
- Phase balancing
- Lockable isolation equipment
- Accessible emergency shutdown
- Protection from coolant leaks and condensation
Incorrect input voltage can damage the rack and installed mining servers. The supply voltage should be tested before energizing the system and monitored during full-load operation.
A qualified industrial electrician should design, install and approve all electrical connections for the Antrack V1.
Operating Environment Requirements
The Antrack V1 has a listed ambient operating range of 15–45°C. It should be installed in a clean, dry environment with adequate access for maintenance, coolant service and emergency shutdown.
| Ambient operating temperature | 15–45°C |
|---|---|
| Storage temperature | -20°C to 70°C |
| Operating humidity | 10–90% RH, non-condensing |
| Coolant pH | 7.8–8.5 |
| Coolant flow | 32–40L/min |
| Maximum water pressure | 3.5 bar |
Condensation must be avoided because moisture can damage electrical connections, control boards and mining equipment. Pipes and fittings may require insulation where coolant temperatures could fall below the surrounding dew point.
Cold-weather installations require sufficient antifreeze protection, while hot environments may need larger external heat exchangers or additional cooling capacity.
Antrack V1 Installation Guide
Installing the Antrack V1 requires coordinated electrical, hydraulic, structural and network preparation. The rack should be commissioned by personnel familiar with industrial power systems and hydro-cooled mining hardware.
- Prepare a level foundation capable of supporting the complete operating weight.
- Confirm delivery access and lifting requirements.
- Position the rack with adequate service clearance.
- Install the required 380–415V three-phase electrical supply.
- Complete grounding, circuit protection and emergency-disconnect systems.
- Install the external coolant piping and heat-rejection equipment.
- Flush the cooling circuit before connecting the miners.
- Pressure-test all hoses, valves and fittings.
- Prepare the approved 10% antifreeze solution.
- Verify that coolant pH is between 7.8 and 8.5.
- Install up to four compatible hydro miners.
- Connect Ethernet networking and monitoring equipment.
- Start the coolant pump before energizing the miners.
- Remove trapped air from the cooling loop.
- Verify a flow rate between 32 and 40L/min.
- Confirm that system pressure remains at or below 3.5 bar.
- Start one miner at a time while monitoring temperature and flow.
Do not operate hydro miners without confirmed coolant circulation. A loss of flow can cause rapid overheating and serious hardware damage.
Stable Hydro Mining Performance
The Antrack V1 can help create more controlled mining conditions than open-air rack installations. Liquid cooling transfers heat directly away from the miner components and reduces dependence on high-speed server fans.
Potential operational benefits include:
- More stable chip temperatures
- Reduced miner-level fan noise
- Less direct exposure to airborne dust
- Compact four-miner deployment
- Organized coolant distribution
- Simplified power and network routing
- Easier system monitoring
Hydro cooling does not automatically guarantee higher profitability. Mining results still depend on the installed servers, Bitcoin price, network difficulty, electricity cost, pool fees, maintenance and uptime.
Antrack V1 Maintenance Requirements
Regular maintenance is essential for protecting the Antrack V1 and its installed hydro miners. Operators should monitor coolant chemistry, water flow, pressure and miner temperatures continuously.
- Inspect hoses, manifolds and fittings for leaks.
- Check pump operation and unusual vibration.
- Verify coolant flow remains between 32 and 40L/min.
- Confirm system pressure remains below 3.5 bar.
- Test coolant pH regularly.
- Measure fluid conductivity according to the maintenance schedule.
- Replace coolant when conductivity reaches the specified limit.
- Remove trapped air from the circulation loop.
- Inspect electrical terminals for overheating.
- Keep the cabinet and service area clean.
- Record temperature, flow and pressure trends.
A gradual rise in miner temperature may indicate restricted flow, degraded coolant, pump wear, trapped air or contamination inside the cooling passages.
Why Choose the Antrack V1?
The Antrack V1 may suit professional miners who want to deploy several hydro servers without investing immediately in a large containerized system. Its four-miner format provides a practical middle ground between a single hydro setup and a full industrial mining container.
Its main advantages include:
- Support for four compatible hydro miners
- 24kW maximum server load
- Compatibility with S19 Hyd. and S21 Hyd. series
- Compact vertical cabinet design
- Industrial three-phase power distribution
- Controlled coolant flow and pressure
- Ethernet connectivity
- 365-day listed warranty
The system is particularly useful for miners who need an organized, repeatable hydro infrastructure platform that can be expanded as the mining operation grows.
Antrack V1 Frequently Asked Questions
What is the Antrack V1?
The Antrack V1 is a BITMAIN hydro cooling rack designed to operate up to four compatible ANTMINER hydro servers.
Is the Antrack V1 an ASIC miner?
No. It is supporting mining infrastructure. The mining servers must be purchased and installed separately.
How many miners can the Antrack V1 hold?
It supports up to four compatible S19 Hyd. or S21 Hyd. series miners.
What is the maximum mining load?
The maximum combined server load is 24kW.
What voltage does the Antrack V1 require?
It requires a three-phase 380–415V AC supply operating at 50–60Hz.
What is the listed input current?
The listed three-phase input current is 80A.
What coolant flow rate is required?
The system requires a flow rate between 32 and 40 litres per minute.
What is the maximum water pressure?
The water pressure should remain at or below 3.5 bar.
What working fluid should be used?
The supplied specification lists a 10% antifreeze solution.
What liquid pH is required?
The recommended pH range is 7.8–8.5.
How large is the Antrack V1?
Its official unpackaged dimensions are 1,000 × 600 × 2,000mm.
How much does the rack weigh?
The official net weight is approximately 205kg, while the packaged gross weight is approximately 310kg.
What is the recommended operating temperature?
The listed ambient operating range is 15–45°C.
How long is the warranty?
The supplied product information lists a 365-day warranty. Buyers should verify coverage, exclusions and the warranty start date before ordering.
Can the Antrack V1 be used at home?
It requires industrial three-phase power, professional coolant plumbing and suitable space. It is generally intended for professional mining facilities rather than ordinary residential installations.
Does the Antrack V1 guarantee mining profitability?
No. Profitability depends on the installed miners, Bitcoin price, mining difficulty, electricity cost, pool fees, maintenance and uptime.
Buy Antrack V1 Hydro Mining Infrastructure
The Antrack V1 combines capacity for four compatible hydro miners, a 24kW maximum load and controlled coolant circulation in one compact professional rack. Its compatibility with S19 Hyd. and S21 Hyd. series miners makes it a practical infrastructure solution for expanding hydro-cooled Bitcoin mining operations.
Before ordering, confirm miner compatibility, three-phase electrical capacity, external heat-rejection equipment, coolant quality, flow requirements and installation space. Visit Hash Titans to compare the Antrack V1 with hydro-cooled ASIC miners and other professional cryptocurrency mining systems.